Compliance Certification Services Inc.
Report No.: 60707201-F Refer No.: 60321204 Date of Issue: July 7, 2006
Page 13 Rev. 00
Procedure of Final Test
l EUT and support equipment were set up on the turntable as per step 8 of the preliminary
test.
l The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and
measured rotating the EUT to 360 degrees, varying cable placement and positioning the
antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal
polarization, to maximize the emission reading level.
l Recorded at least the six highest emissions. Emission frequency, amplitude, antenna
position, polarization and turntable position were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit and only Q.P. reading is presented.
l The test data of the worst case condition(s) was recorded.
Data Sample:
Freq.
MHz
Amptd
dBuV/m
Margin
dB
Limit
dBuV/m
Reading
dBuV
Factor
dB/m
Reading
Type
(P/Q/A)
Pol.
(H/V)
x.xx 26.2 -13.8 40 14 12.2 Q H
Freq. = Emission frequency in MHz
Read Level = Uncorrected Analyzer/Receiver reading
Factor = Antenna Factor + Cable Loss + Attenuator (3/6/10dB) – Amplifier Gain
Level = Read Level + Factor
Limit = Limit stated in standard
Over Limit = Reading in reference to limit
P = Peak Reading
Q = Quasi-peak Reading
A = Average Reading
H = Antenna Polarization: Horizontal
V = Antenna Polarization: Vertical
Calculation Formula
Over Limit (dB) = Level (dBuV/m) Limit (dBuV/m)