Compliance Certification Services Inc.
Report No.: 40614203-D Date of Issue: July 15, 2004
Page 18 Rev. 00
Line Conducted Emission
Model: PPC-V106 Test Mode: Mode 5
Temperature: 27°C
Humidity: 60% RH
Tested by: Carl Chang Test Results: Pass
(The chart below shows the highest readings taken from the final data)
L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Note: “---” denotes the emission level was or more than 2dB below the Average limit, so no re-check anymore.
Q.P. AVG Q.P. AVG Q.P. AVG
Raw Raw Limit Limit Margin Margin
(dBuV) (dBuV) (dBuV) (dBuV) (dB) (dB)
0.170 49.80 --- 64.96 54.96 -15.16 --- L1
1.608 27.30 --- 56.00 46.00 -28.70 --- L1
3.846 25.20 --- 56.00 46.00 -30.80 --- L1
4.482 33.70 --- 56.00 46.00 -22.30 --- L1
5.458 29.80 --- 60.00 50.00 -30.20 --- L1
8.326 30.50 --- 60.00 50.00 -29.50 --- L1
0.174 48.70 --- 64.77 54.77 -16.07 --- L2
2.242 25.90 --- 56.00 46.00 -30.10 --- L2
3.848 30.00 --- 56.00 46.00 -26.00 --- L2
4.308 35.60 --- 56.00 46.00 -20.40 --- L2
6.088 27.10 --- 60.00 50.00 -32.90 --- L2
8.036 30.50 --- 60.00 50.00 -29.50 --- L2
Freq.
(MHz)
NOTE