13 Chapter 2
2.4 Terminal Resistor Setup for RS-422/485
The onboard termination resistor (120 Ohm) for COM1-6, COM A,
and COM B can be used for long distance transmission or device match-
ing (Default Open).
Each terminal resistor responds to different channels for RS-422/485.
Usually, these resistors are needed for both ends of the communication
wires and the value of the resistors should match the characteristic imped-
ance of the wires used.
Terminal Resistor Settings
COM Port Switch Pin Setting Description
COM 1,2 SW 11 1 (COM1) ON 120 Ohm between Data+/
Data-
OFF Open (Default)
2 (COM2) ON 120 Ohm between Data+/
Data-
OFF Open (Default)
COM A
COM B
SW 10
SW 9
1 ON 120 Ohm between Data+/
Data- (RS-485 COM A, B
only)
Or 120 Ohm between Tx+/
Tx-
(RS-422)
OFF Open (Default)
2 ON 120 Ohm between Rx+/Rx-
(RS-422)
OFF Open (Default)
COM 3
COM 4
COM 5
COM 6
SW 6 1 (COM3) ON 120 Ohm between Data+/
Data-
2 (COM4)
3 (COM5) OFF Open (Default)
4 (COM6)