27 Chapter 4
The IRQ and the address ranges for COM1, 2, 3, and 4 are fixed. How-
ever, if you wish to disable the port or change these parameters later you
can do this in the system BIOS setup. The table overleaf shows the
default settings for the panel PC’s serial ports.
COM1 and COM2 are one set. You can exchange the address range and
interrupt IRQ of COM1 for the address range and interrupt IRQ of
COM2. After exchanging, COM1's address range is 3F8 ~ 3FF and its
request IRQ is IRQ4: and COM2's address range is 2F8 ~ 2FF and its
interrupt IRQ is IRQ3.
COM3 and COM4 are another set. Their address and IRQ is the same as
the COM1/COM2 set
Table 4.4: COM2 RS-232/422/485 setting (J2)
*RS-232
RS-422
RS-485
* default setting