3.2.15 EasyDualFAICheck
Checks whether the asynchronous, multiple-channel data acquisition operation is complete or not
and return current status.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Count Specifies the buffer size to be transferred
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
FAICheck A cluster containing ActiveBuf, stopped, retrieved
and overrun data
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in