Quick Start Example
0F = set input range to type K thermocouple
00 = set data format to engineering units, 50ms (60Hz)
(See Chapter 6, Command Set for a full description of the syntax of the
configuration command for an analog input module)
When the module received the configuration command it will respond
with its new address:
!01(cr)
Wait 7 seconds to let the new configuration settings take effect before
issuing a new command to the module.
Note:
All reconfiguration except changing of baud rate and
checksum values can be done dynamically, i.e. the
modules need not be reset.
When changing baud
rate or checksum, these changes should be made for
all connected devices. After reconfiguration, all
modules should be powered down and then powered
up to force a reboot and let the changes take effect.
See the next section for a strategy for changing baud
rate and or checksum for an entire network.
A.3 Baud Rate and Checksum
ADAM-5000 systems contain an EEPROM to store configuration
information and calibration constants. The ROM replaces the usual
array of switches and pots required to specify baud rate, input/output
range, etc. The ADAM-5000 system can be configured remotely
through their communication ports, without having to physically alter
pot or switch settings.
Since there is no visual indication of a system's configuration status, it
is not possible to visually determine baud rate and other system
settings. It might not be possible to establish communications with a
system whose baud rate and address are unknown. To overcome this
problem, every system has an input terminal labeled INIT*. By
booting the system while connecting the INIT* terminal with the
system's GND terminal, the system configuration is forced into a
A-8 ADAM-5000
Zobrazit stránku 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 300 301

Komentáře k této Příručce

Žádné komentáře

ETC Unison Heritage Contact and Fader Interface Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Schalttafel ETC Unison Heritage Contact and Fader Interface.
Wir stellen 1 PDF-Handbücher ETC Unison Heritage Contact and Fader Interface zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Schalttafel ETC

Modelle Dokumententyp
Unison Heritage Rackmount Contact Interface Bedienungsanleitung   ETC Unison Heritage Rackmount Contact Interface User Manual, 3 Seiten
Unison Heritage Consolette Station Bedienungsanleitung   ETC Unison Heritage Consolette Station User Manual, 1 Seiten
Unison Heritage Fader Station Bedienungsanleitung   ETC Unison Heritage Fader Station User Manual, 4 Seiten