15-4
Smart Web Ethernet I/O Modules
ADAM-6000 Series
The ADAM-6000 is a controller independent, distributed I/O solution with modular design
for maximum flexibility. Its powerful onboard intelligence makes it well suited to SCADA
and stand-alone control applications.
Ethernet-Enabled Networking
The ADAM-6000 series Ethernet-enabled data acquisition and control module works as an
Ethernet I/O data processing center. This new product is not only a standard I/O, but also
an intelligent system designed with local control functions and a Modbus/TCP standard
for users to easily develop various applications over Ethernet.
Analog Input Modules
The ADAM-6000 analog input modules use microprocessor-controlled, high-resolution,
16-bit, sigma-delta A/D converters to acquire sensor signals such as voltage, current,
thermocouple or RTD. They translate analog data into two’s complement. After the modules
receive a request from the host, they send the data in the desired format over the Ethernet
network. ADAM-6000 analog input modules protect your equipment from ground loops
by providing 3000 V
DC
isolation. The ADAM-6017 and ADAM-6018 modules feature
digital outputs which may also be used for alarms and event counting. The analog input
module’s two digital output channels are open-collector transistor switches that you can
control from the host computer. By switching solid state relays, the output channels can
control heaters, pumps and other power equipment. The module can use its digital input
channel to sense the state of a remote digital signal.
Programmable Alarm Output
Analog input modules include high and low alarm signals with remotely configurable
boundary values. After each A/D conversion, the digital value is compared with the high
and low limit. The module can change the state of a digital output depending on the
result of this comparison. This function allows it to perform on/off control of a device
independently of the host PC.
Independent Channel Input Type
Configuration
The ADAM-6015 6-channel RTD module, provides independent channel input type
configuration. You can configure PT-100, Pt-1000 or Balco mA for each channel. This
independent channel input type configuration gives the ADAM-6015 more flexibility for
versatile applications. This functionality saves customers the cost of buying multiple
modules and reduces inventory as well.
System Architecture
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com